1-866-494-4610

Testo 0563.3372.71 Combustion Analyzer

Testo 0563.3372.71 Combustion Analyzer
Images for general purposes only. Actual may be different than depicted.
Testo 0563.3372.71 Combustion Analyzer

Testo 0563.3372.71 Combustion Analyzer

SKU: 0563.3372.71
Rating:
Quantity Price Stock
Usually Ships 2 - 4 Days
Usually Ships 2 - 4 Days
$4,916.14     /ea
Usually Ships 2 - 4 Days
0
$0.00
0
$0.00
0
0563.3372.71

TESTO 330-2G LL COMBUSTION ANALYZER KIT #1, O2, CO
 

  • In CO measurement, from 8.000 ppm, automatic dilution is carried out up to min. 30,000 ppm CO
  • Integrated gas and draught zeroing without probe removal: The probe can remain in the flue during zeroin
  • New instrument design
  • Instrument diagnosis function uses easy ãtraffic light presentation to enable comprehensive error diagnosis, diagnosis of sensors and the call-up of instrument information such as the filling level of the condensate trap and the battery status
  • Logger function for long-term measurements
  • New measurement menus: Gas pipe test and solid fuel measurement for CO / O2
  • Pressure measurement up to 300 mbar
  • User-defined fuels
  • Reduced follow-on costs thanks to LL sensors with 4 year guarantee
  • Life expectancy up to 6 years (O2 / CO)
  • At least 1 sensor replacement is saved in the course of a normal working life
  • Powerful Li-ion rechargeable battery - life: >10 h with pump running, no memory effect, no deep discharge
  • Rechargeable battery can be charged separately and in instrument
  • T†V-tested according to 1. BImSchV / EN 50379 Part 2 for O2, °C, hPa and CO with H2-compensation
  • Powerful memory management: 500,000 readings
  • IrDa/ Bluetooth interface for data transfer to Pocket-PC / laptop / printer
  • USB interface for data readout to a PC software
  • ZIV (Central Guild Association) driver for all standard industry software package

    Specifications:
    Functional Specifications
    Temperature
    Range: -40 to +1200°C
    Accuracy: ±0.5°C (0.0 to +100.0°C; ±0.5 % of mv (remaining range)
    Resolution: 0.1 °C (-40 to 999,9 °C); 1 °C (remaining range)

    Draught measurement
    Range: -9.99 to +40 hPa
    Accuracy (the greater value applies): ±0.02 hPa or ±5% of mv (-0.50 to +0.60 hPa); ±1.5% of mv (+3.01 to +40.00 hPa)
    Resolution: 0.01 hPa

    Pressure measurement
    Range: 0 to 300 hPa
    Accuracy: ±0.5 hPa (0.0 to 50.0 hPa); ±1% of mv (50.1 to 100.0 hPa); ±1.5 % of mv (remaining range)
    Resolution: 0.1 hPa

    O2 measurement
    Range: 0 to 21 Vol. %
    Accuracy: ±0.2 Vol. %
    Resolution: 0.1 Vol. %
    Adjustment time t90: <20 s

    CO measurements (without H2 compensation)
    Range: 0 to 4000 ppm
    Resolution: 1 ppm
    Accuracy: ±20 ppm (0 to 400 ppm); ±5% of mv (401 to 1000 ppm); ±10% of mv (1001 to 4000 ppm)
    Adjustment time t90: <60 s

    Efficiency (ETA)
    Range: 0 to 120%
    Resolution: 0.1%

    Flue gas loss
    Range: 0 to 99.9%
    Resolution: 0.1%

    CO2 measurement
    Display range: 0 to CO2 max
    Resolution: 0.1 Vol. %
    Accuracy: ±0.2 Vol. %
    Measurement: Digital calculation from O2
    Adjustment time t90: <40 s

    Option: CO low measurement
    Range: 0 to 500 ppm
    Resolution: 0.1 ppm
    Accuracy: ±2 ppm (0.0 to 40.0 ppm); ±5% of mv (remaining range)
    Adjustment time t90: <30s

    General Specifications
    Memory: 500.000 readings
    Weight: 600 g (without rechargeable battery)
    Dimensions: 270 x 90 x 65 mm
    Display: Colour graphic display with 240 x 320 Pixel
    Power supply: Rechargeable battery pack 3.7 V / 2.6 Ah Mains unit 6 V / 1.2 A

     

Q & A: Ask the Questions, share answers